Review began 07/19/2022 review ended 07/25/2022 published 07/30/2022 © copyright

HIGHLIGHTS

SUMMARY

    In this retrospective study, the safety and complication rates of port implantations via the internal jugular vein under ultrasound and fluoroscopy guidance in adult oncology patients were analyzed. The technical success rate was 99.9%, and a total of 85 (10.5%) complications occurred, of which 24 (28.2%) occurred early ( and amp;lt;30 days) and the remaining 61 (71.8%) were late (>30 days) complications. Specifically, 28 (3.5%) were catheter-related thrombosis (CRT), 27 (3.4%) related to infection, 17 (2.1%) were mechanical complications (16 fibrin sheath formation and one . . .

     