HIGHLIGHTS
- who: Vascular prosthesis and colleagues from the cente, disciplina Cirurgia, (FAMEMA), (FMB), Universidade Estadual (UNESP), SP, Brazil have published the article: Factors involved in the migration of endoprosthesis in patients undergoing endovascular aneurysm repair, in the Journal: (JOURNAL)
SUMMARY
The authors established that the greater the distance from the renal artery to the proximal end of the graft, the greater the risk of migration; each millimeter increase in distance below the renal arteries increased risk of migration by 5.8%. Adequate placement of the distal end of the graft near the origin of . . .