Modified electrodeposited cobalt foam coatings as sensors for detection of free chlorine in water

HIGHLIGHTS

  • who: Modestas Vainoris et al. from the Department of Physical Chemistry, Vilnius University, Naugarduko str24, Vilnius, Lithuania have published the research: Modified Electrodeposited Cobalt Foam Coatings as Sensors for Detection of Free Chlorine in Water, in the Journal: (JOURNAL)
  • what: __SECTION__ Conclusions.
  • how: The influence of the cathodic current density on the foam's formation revealed the following aspects From the chloride-based solution the foam-like structure was obtained only at cathodic current densities ˃1.8 A/cm² . The best results were obtained using -0.45 V vs Ag/AgCl potential order . . .

     